Rating
Reviews
Name: Israel Beltran
College: He graduated from Mayfield College (HVAC) and has certifications in HVAC, EPA, forklift operator and business management.
Favorite Aspect of My Job: Izzy’s favorite aspect of his job is being able to learn new things about HVAC and the ability to do ten things at once.
Hobbies: When he is not working and supervising at Hydes, Izzy enjoys spending time with family and hobbies that include, sports, cars and music.
Interesting Fact About Me: Israel a.k.a. “Izzy” has been a part of the Hydes work family for over two years although he has worked in the HVAC industry for seven years.
Customers say: The reviews exhibit a positive overall sentiment, with a majority of customers expressing satisfaction with the services provided by Hyde's AC. The recurring themes include praise for the technicians' expertise, professionalism, and courtesy. Customers also appreciate the prompt and efficient service, with many highlighting the technicians' ability to address issues quickly and effectively. Additionally, the company's reputation for honesty, integrity, and quality workmanship is frequently mentioned. Negative reviews are present but are outweighed by the positive ones. The negative reviews primarily focus on minor issues or misunderstandings, with customers expressing gratitude for the prompt resolution of their concerns. Overall, the sentiment is positive, with customers expressing satisfaction with the company's services and technicians.
on time and quick
Never met or saw the man. I can but assume he came by to collect the ladder late today. Thank you after three days of it being here. Unlike Hyde's usual great service.
Very knowledgeable, patient and was able to address our concerns. Thank you.
Sometimes your hvac system can be tricky. Especially so when you have a Generac- as I do. They diagnosed and fixed quickly. No charges for a trip where it ended in a non repair. Some places have minimums for a trip that was fruitless. HVAC is already expensive work. It can get worse with petty and unnecessary charges. I used to be in the hvac bus.
Israel showed up on time to complete a job on time. Thanks Israel.
The service tech was the best. Miguel. He explained things so that I could follow the technology easily. He did the repair with great care. He left the work site very clean. happy customer
Gave extra effort
Very professional
I have always had excellent service from Hyde’s. Their technicians are polite and professional. Very knowledgeable of their job
The service person, Israel, was very thorough. He explained everything he was going to do from the start and then when he was finished, he went over everything that he did do. He articulated very well and was very professional and friendly. He was very respectful of our property inside and out, and I would recommend him and your company to anyone that needs service on their air/heating units.
Tech arrived on time. Was very professional. Explained everything clearly
Miguel did a great job, polite, thorough explanation of what he was going to do. did it very respectfully of the time in the house and finished with an evaluation of what he found. Definitely happy with the maintenance and reinforced our expectation of service when our new system was installed. Very satisfied as I don't always give top ratings. Thanks for asking.
Response from Hydes Air Conditioning:
Thank you for your kind words, Jim! We appreciate your business and are glad to hear that you are satisfied with our maintenance services. We look forward to serving you again in the future and we will do our best to keep impressing you!
Open arrival found generator cranking, but not starting upon further investigation found too much fuel, preventing generator to start, adjusted gas valve and generator started running but gas regulator inside generator maybe the cause of to much gas . This is just a temporary fixed may need to change gas regulator.
Took out old equipment, crane down condensers and lift up new ones
Lennox outdoor unit client stated everything’s running just not cooling the home. Well unit holds 10 pounds of refrigerant for 10 a target is 10.6 sub cool gauges read 2° sub cool estimate 5 to 6 pounds
Outdoor unit serial number KA2F faulty dual run capacitor—- indoor blower is running——Refrigerant number good (10.7sc)and starting amps good. Client had a service April 18—- considering this call a follow up—-under 30 days
Quote to install a 30 gallon electric Bradford White "Low Boy" water heater. Includes city permits.
Generator is exercising as it should every first of the month at 12 o’clock for five minutes told customer if I have to come back out for any other reason he will be charged a service fee for coming out. Also recommended maintenance for generator! generator, flashing green and yellow for service maintenance due. Customer denied maintenance.
Client was called --LM please call back ask for greg----i did send an estimate to
Replace and put in a new blower motor. Also clean housing for blower motor after installing tested out unit, at this time system is cooling down the house properly blower motor is also working properly.
Serial # 285f,,,Replace compressor under part warranty,,,,vacuum system to 500 microns system cooling properly
Picked up ladder
Client was called—-explain the hold function on all three thermostats—-client was experiencing temperature change while he was away due to thermostats on a schedule—-all thermostats are on hold mode. Should be good to go.
Installed smm on mini split for garage
See Greg’s report
An installation of a 2.5-ton American Standard Silver 14 split heat pump was successfully completed. In addition to this primary task, we meticulously conducted a thorough inspection of the system to ensure optimal performance and energy efficiency. Our team focused on verifying all connections and assessing the overall setup to guarantee that it meets the highest standards. We also provided recommendations for ongoing maintenance to enhance the longevity and reliability of the equipment. We installed a 2 1/2 ton silver 14.
Installing 4 Ton Silver 15 Horizontal Split Heat Pump System for bedrooms with Sensi Non-Wifi thermostat. we installed a 4 ton silver 15 system with a new Plenum.
Quote to install a 4 ton American Standard Silver 15 up flow heat pump system. Clean up supply plenum. This mobile home park requires permit be pulled thru the State of California. This system qualifies for the 2000.00 federal tax credit. 18 months no interest financing thru Wells Fargo available
Replace condenser and evaporator hola system straight cool
Quote to install 1.5 ton 18 seer Mitsubishi ductless for the garage.
Could not connect to Wi-Fi. Put a new Kumo cloud in same thing happen could not connect to Wi-Fi.
Perform a cooling maintenance on 2021 American standard platinum series condenser. condenser located on left side of home, filter located in hallway, ceiling filter, change filter, flushed condensation line from outside, condensation light on left side of home, check for amperage in voltage, check for compressor, check for data plate no errors codes, check for Freon level, clear out dust from electrical component area, rinse condenser. System working within specification in cooling at the time of maintenance.
Performed a cooling maintenance on 3 ton and a 5 ton American standard platinum series condenser. condenser located on right side of home,filters located inside furnace, furnace located in garage 20x24 and 16x25 filter. Change filter, flush, condensation line, check for amperage and voltage ,check for compressor, check for Freon, Level, clear dust from electrical component area. Rinsedboth condensers. Both units working and cooling with the specifications at the time of maintenance.(client left could not collect advices office )
Perform a cooling maintenance on it 5 ton American standard gold series, check for amperage voltage check for capacitor. Check for Freon level cleared out dust from electrical component area system working with the specification. Also for living from condenser serial SERIAL E180704598 check for amperage voltage, check for capacitor which was low processed to ask HO if wanted to change accepted and changed it (70/7.5) Check for Freon level, cleared out dust from electrical component area, flushed condensation line for both units. Both systems working within specification in cooling at the time of maintenance.
Picked up tray
Perform a cooling maintenance on a 4 ton American standard silver series condenser, condenser located on left side of home, filter located in hallway, ceiling filter, change filter, flushed condensation line from outside, condensation line on left side of home, check for amperage and voltage in condenser, check for capacitor, clear dust from electro component area, check for compressor, check for Freon level, rinsed condenser. System working with the specification, including at time of maintenance.
Performed a cooling maintenance on a 2022 American standard silver series, condenser located on left side of home, condensation line located on right side of home, filter located in ceiling hallway, change filter, flushed condensation line, check for voltage in amperage, check for capacitor, check for Freon level, clear, dust away from electro component area, washed condenser. System working with the specification, including at the time of maintenance.